Description
Radiant Warmer
Nest-500
Far Infrared Ceramic Heating Tube
- Utilize Elstein far infrared ceramic heating tube, which greatly improves radiation efficiency and extends the service life.
- Perfectly absorbed by the skin, it effectively accelerates blood circulation, allowing visceral and body surface temperatures to rise simultaneously in a short time.
- Double heating tube design accelerates the heating rate and ideally distributes heat evenly, even when the mattress is tilted, providing a warm and comfortable environment for neonates.
- Apply a high-accuracy double thermistor temperature sensor to increase the accuracy of temperature monitoring.
Nest-500
NEST 500 is equipped with environmentally friendly silicone gel, offering higher biocompatibility and excellent thermal performance. It provides enhanced comfort, reduced bedsores, and antibacterial properties, while being easy to clean and disinfect.

NEST 550

NEST 500
| Storage/Shipping Information | |
|---|---|
| Temperature control | -25°~60°C |
| Humidity | 0~95% RH |
| Power requirements | 230W |
| Heater capacity | 500W |
| Canopy mobility range | Horizontal rotation 320° (160° both clockwise and counterclockwise) Radiation range |
| Temperature control | Servo(Baby)mode/Manual/Preheating mode |
| Skin temperature | Setting range:34.0°~38.0°C Accuracy:±3% Display range:20.0°~42.0°C |
| Heater output | Setting range:0°~100% (in 5% increments) Indication range:0°~100% (in 1% increments) |
| Timer | APGAR mode/CPR, mode switchable APGAR Beep:1,3, (option),5,10 min |
| Examination Lighting | Power: 6W LED(2W×3) LED lamp Adjustable illumination intensity:0°1500 lux |
| LCD display | 10.4" LCD touch screen Pixel:800x600 |
| Bed tray | Inclination angle(back and forth): ±13° Mattress surface:500x700x25mm Mattress surface to ground height(standard):90cm Guard door:damping system Cable access hole:3 |
| Dimensions | 84(W)x110(D)x186(H) cm (standard) |
| Net weight | 90 Kg |
| Alarms silence | Hand free |
| Height adjustment | Up to 30 cm |
| MODEL | NEST 550 | NEST 500 |
|---|---|---|
| Weight scale | ||
| Weight range Weight display resolution Weight accuracy |
300 g to 8000 g 1 g ±10 g |
â—‹ |
| X-ray cassette | ||
| Dimension | 33x35 cm | â—‹ |
| Weight limit | Drawer 5 Kg |
â—‹ |
| Pulse Oximeter Unit | ||
| Display range Display accuracy Pulse rate display range Pulse rate display accuracy |
0 to 100% SpO₂ ±2% (70 to 99%) 30 to 240bpm 1% +1 bpm |
â—‹ |
| Resuscitation | ||
| Manometer Resusci-flow unit |
Pressure Indication:-2 to10 KPa (-20 to 100cm H₂O) PMAX setting range: ≤6KPa(60cmH₂O) |
â—‹ |
| Suction Unit | ||
| Negative pressure range | Suction pressure control range: 24~0 KPa(-180~0 mmHg) | â—‹ |